Function Reference | ![]() ![]() |
Initialize an LTI Viewer for LTI system response analysis
Syntax
ltiview ltiview(sys1,sys2,...,sysn) ltiview('plottype
',sys1,sys2,...,sysn) ltiview('plottype'
,sys,extras) ltiview('clear',viewers) ltiview('current',sys1,sys2,...,sysn,viewers)
Description
ltiview
when invoked without input arguments, initializes a new LTI Viewer for LTI system response analysis.
ltiview(sys1,sys2,...,sysn)
opens an LTI Viewer containing the step response of the LTI models sys1,sys2,...,sysn
. You can specify a distinctive color, line style, and marker for each system, as in
initializes an LTI Viewer containing the LTI response type indicated by ltiview('
plottype'
,sys)
plottype
for the LTI model sys
. The string plottype
can be any one of the following:
plottype
can be a cell vector containing up to six of these plot types. For example,
displays the plots of both of these response types for a given system sys
.
ltiview(
allows the additional input arguments supported by the various LTI model response functions to be passed to the plottype
,sys,extras)
ltiview
command.
extras
is one or more input arguments as specified by the function named in plottype
. These arguments may be required or optional, depending on the type of LTI response. For example, if plottype
is 'step'
then extras
may be the desired final time, Tfinal
, as shown below.
However, if plottype
is 'initial'
, the extras
arguments must contain the initial conditions x0
and may contain other arguments, such as Tfinal
.
See the individual references pages of each possible plottype
commands for a list of appropriate arguments for extras
.
ltiview('clear',viewers)
clears the plots and data from the LTI Viewers with handles viewers
.
ltiview('current',sys1,sys2,...,sysn,viewers)
adds the responses of the systems sys1,sys2,...,sysn
to the LTI Viewers with handles viewers
. If these new systems do not have the same I/O dimensions as those currently in the LTI Viewer, the LTI Viewer is first cleared and only the new responses are shown.
ltiview(plottype
,sys1,sys2,...sysN) ltiview(plottype
,sys1,PlotStyle1,sys2,PlotStyle2,...) ltiview(plottype
,sys1,sys2,...sysN,extras)
initializes an LTI Viewer containing the responses of multiple LTI models, using the plot styles in PlotStyle
, when applicable. See the individual reference pages of the LTI response functions for more information on specifying plot styles.
See Also
bode
Bode response
impulse
Impulse response
initial
Response to initial condition
lsim
Simulate LTI model response to arbitrary inputs
nichols
Nichols response
nyquist
Nyquist response
pzmap
Pole/zero map
sigma
Singular value response
step
Step response
![]() | ltiprops | lyap | ![]() |